You have reached this page because of your interest in the Power Supply NSN parts we have in stock on Astral Parts. Here, you are provided the opportunity to submit a quote request for Hdl Research Lab Inc part number 200100, a component which is readily available for purchase and that can be found by searching for NSN 6130010126676 in our database. Apart from carrying part number 200100, our inventory also features a wide range of others, such as military, defense, and aerospace parts. More than that, we make it our priority to only source from trusted global entities on our Approved Vendor List (AVL).
Note : We Will Not Share Your Information To Any Third Parties.
At Astral Parts, we work with numerous government and defense agencies, meaning that we utilize the CAGE Code system to organize our partnerships with various manufacturers, including CAGE Code 66015, under which Hdl Research Lab Inc operates. More than that, we take advantage of Federal Supply Classes (FSCs) like FSC 6130 Converters Electrical Non Rotating, ensuring that you receive the exact item you desire and that will work with your applications. Submit the form below for part number 200100 and see how Astral Parts is simplifying the fulfillment process by adhering to a straightforward process that guarantees you get what you need as fast as possible.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-012-6676 Item PartTypeName: POWER SUPPLY | 6130 | 010126676 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
STM5-2Y | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 9.500 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 3.312 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 5.125 INCHES NOMINAL |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | SINGLE 1ST OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 105.0 AC POUNDS PER HOUR DRY AND 132.0 AC VOLTS MAXIMUM 1ST OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 127.5 DC POUNDS PER HOUR DRY AND 172.0 DC VOLTS MAXIMUM 2ND OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 4.5 DC VOLTS MINIMUM SINGLE POWER OUTPUT AND 6.0 DC VOLTS MAXIMUM SINGLE POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 50.0 HERTZ MINIMUM 1ST OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 1ST OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | 0.1/71.0 DEG CELSIUS |
BGHX | OUTPUT CONTROL QUANTITY | 1 SINGLE POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT SINGLE POWER OUTPUT |
BHQN | RECTIFICATION METHOD | SINGLE PHASE FULL WAVE BRIDGE |
CBBL | FEATURES PROVIDED | FILTER |
CWGH | OUTPUT CURRENT RATING | 9.6 DC AMPERES MINIMUM SINGLE POWER OUTPUT AND 24.0 DC AMPERES MAXIMUM SINGLE POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 SINGLE POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP SINGLE POWER OUTPUT |
FEAT | SPECIAL FEATURES | INPUT VOLTAGES DO NOT OPERATE CONCURRENTLY |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.