You have reached this page because of your interest in the Transformerpower NSN parts we have in stock on Astral Parts. Here, you are provided the opportunity to submit a quote request for Magnetika Inc part number APS-064, a component which is readily available for purchase and that can be found by searching for NSN 5950004954663 in our database. Apart from carrying part number APS-064, our inventory also features a wide range of others, such as military, defense, and aerospace parts. More than that, we make it our priority to only source from trusted global entities on our Approved Vendor List (AVL).
Note : We Will Not Share Your Information To Any Third Parties.
At Astral Parts, we work with numerous government and defense agencies, meaning that we utilize the CAGE Code system to organize our partnerships with various manufacturers, including CAGE Code 15634, under which Magnetika Inc operates. More than that, we take advantage of Federal Supply Classes (FSCs) like FSC 5950 Coils and Transformers, ensuring that you receive the exact item you desire and that will work with your applications. Submit the form below for part number APS-064 and see how Astral Parts is simplifying the fulfillment process by adhering to a straightforward process that guarantees you get what you need as fast as possible.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-495-4663 Item PartTypeName: TRANSFORMER,POWER | 5950 | 004954663 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
890827 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.060 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.060 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.060 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENTTHREE PHASE TO THREE PHASE SINGLE COMPONENTTHREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 4.250 INCHES NOMINAL4.250 INCHES NOMINAL4.250 INCHES NOMINAL |
ADAT | BODY WIDTH | 2.950 INCHES NOMINAL2.950 INCHES NOMINAL2.950 INCHES NOMINAL |
ADAU | BODY HEIGHT | 2.370 INCHES NOMINAL2.370 INCHES NOMINAL2.370 INCHES NOMINAL |
AEHZ | MAXIMUM OPERATING TEMP | 155.0 DEG CELSIUS |
AGAV | END ITEM IDENTIFICATION | WSD: AIRCRAFT,PHANTOM F-4 |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSEDFULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUPTHREADED HOLE SINGLE GROUPTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 8 SECONDARY SINGLE COMPONENT8 SECONDARY SINGLE COMPONENT8 SECONDARY SINGLE COMPONENT |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP32 SINGLE GROUP32 SINGLE GROUP |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP0.164 INCHES SINGLE GROUP0.164 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 1.1 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 178.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 189.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 310.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 22.0 WATTS SINGLE COMPONENT SINGLE PRIMARY |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CWJS | WINDING OPERATING VOLTAGE | 17.90 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY188.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY17.90 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 31.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 31.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY17.90 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY31.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 46.90 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 46.90 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY17.90 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY46.90 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
FEAT | SPECIAL FEATURES | 5TH SECONDARY 10.5V 118 MA,6TH SEC 10.5V 275 MA,7TH SEC 71.0V 1.5A,8TH SEC 77.5V 1.68A; WEAPON SYSTEM ESSENTIAL |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 27 PIN |