You have reached this page because of your interest in the Circuit Breaker NSN parts we have in stock on Astral Parts. Here, you are provided the opportunity to submit a quote request for Siemens Energy And Automation Inc part number Q230HM, a component which is readily available for purchase and that can be found by searching for NSN 5925013119919 in our database. Apart from carrying part number Q230HM, our inventory also features a wide range of others, such as military, defense, and aerospace parts. More than that, we make it our priority to only source from trusted global entities on our Approved Vendor List (AVL).
Note : We Will Not Share Your Information To Any Third Parties.
At Astral Parts, we work with numerous government and defense agencies, meaning that we utilize the CAGE Code system to organize our partnerships with various manufacturers, including CAGE Code 66842, under which Siemens Energy And Automation Inc operates. More than that, we take advantage of Federal Supply Classes (FSCs) like FSC 5925 Circuit Breakers, ensuring that you receive the exact item you desire and that will work with your applications. Submit the form below for part number Q230HM and see how Astral Parts is simplifying the fulfillment process by adhering to a straightforward process that guarantees you get what you need as fast as possible.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-311-9919 Item PartTypeName: CIRCUIT BREAKER | 5925 | 013119919 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Q230HM | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | RECTANGULAR DIMENSIONAL ENVELOPE |
ABHP | OVERALL LENGTH | 2.875 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 2.000 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 2.375 INCHES NOMINAL |
AKPX | POLE QUANTITY | 2 |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 CLIP AND 2 TERMINAL |
BBRJ | SPECIAL HANDLING FEATURE | MAGNETIC |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 30.0 AMPERES AC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 22000.0 AC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 2 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE AND TWO LINKED |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CWJK | CASE MATERIAL | PLASTIC |
FEAT | SPECIAL FEATURES | 50 DEGREES CELSIUS CALIBRATION FOR MARINE APPLICATION INCLUDED |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
TTQY | TERMINAL TYPE AND QUANTITY | 2 CLIP AND 2 COMPRESSION |